1.
Artif Organs ; 48(2): 130-140, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37860931

RESUMO

BACKGROUND: Although extracorporeal membrane oxygenation (ECMO) has been used to provide temporary support for pediatric patients suffering severe respiratory or cardiac failure since 1970, ECMO systems specifically designed for pediatric patients, particularly for long-term use, remain an unmet clinical need. We sought to develop a new pediatric ECMO system, that is, pediatric pump-lung (PPL), consisting of a unique cylinder oxygenator with an outside-in radial flow path and a centrifugal pump. METHODS: Computational fluid dynamics was used to analyze the blood fluid field for optimized biocompatible and gas exchange performances in terms of flow characteristics, hemolysis, and gas transfer efficiency. Ovine blood was used for in vitro hemolysis and gas transfer testing. RESULTS: Both the computational and experimental data showed that the pressure drop through the PPL's oxygenator is significantly low, even at a flow rate of more than 3.5 L/min. The PPL showed better hemolysis performance than a commercial ECMO circuit consisting of the Quadrox-iD pediatric oxygenator and the Rotaflow pump at a 3.5 L/min flow rate and 250 mm Hg afterload pressure. The oxygen transfer rate of the PPL can reach over 200 mL/min at a flow rate of 3.5 L/min. CONCLUSIONS: The PPL has the potential to provide adequate blood pumping and excellent respiratory support with minimal risk of hemolysis for a wide range of pediatric patients.


Assuntos
Oxigenação por Membrana Extracorpórea , Hemólise , Humanos , Criança , Animais , Ovinos , Hidrodinâmica , Oxigenação por Membrana Extracorpórea/efeitos adversos , Pulmão , Oxigenadores , Desenho de Equipamento
2.
Ann Biomed Eng ; 52(3): 638-646, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38062312

RESUMO

We demonstrate a methodology which both improves oxygen transport and reduces or eliminates bubble formation in a novel hyperbaric membrane oxygenator catheter model system. Angular oscillations were introduced to a bundle of hollow fiber membranes (HFMs) supplied with hyperbaric 100% oxygen at average gauge pressures up to 0.35 barg. Oscillating bundles enabled delivery of an oxygen flux of up to 400 mL min-1 m-2 in an aqueous solution, a doubling over a previous non-oscillating setup. Similarly, the addition of angular oscillations facilitated a five-fold reduction in pressure to achieve similar oxygen flux. The increased angular speed of oscillation improved flux, while the addition of angular micro-oscillation variations resulted in flux reductions of 7-20% compared to continuous macro-oscillation only, depending on mixing conditions. However, semi-quantitative visual observation demonstrated that angular oscillations reduced or eliminated the instance of oxygen bubble formation on the HFMs. The modeled mass transfer coefficients indicated a quasi linear relationship between rotational velocity and flux, suggesting that faster oscillation speeds could further improve oxygen mass transport allowing for HFM bundles to maintain high oxygen fluxes while eliminating bubble formation. This encourages further development of our compact oxygenating catheter that could be used intravascularly.


Assuntos
Oxigênio , Oxigenadores , Cateteres , Desenho de Equipamento , Oxigenadores de Membrana
3.
Semin Thromb Hemost ; 50(2): 253-270, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37640048

RESUMO

Extracorporeal membrane oxygenation (ECMO) is a life-support technique used to treat cardiac and pulmonary failure, including severe cases of COVID-19 (coronavirus disease 2019) involving acute respiratory distress syndrome. Blood clot formation in the circuit is one of the most common complications in ECMO, having potentially harmful and even fatal consequences. It is therefore essential to regularly monitor for clots within the circuit and take appropriate measures to prevent or treat them. A review of the various methods used by hospital units for detecting blood clots is presented. The benefits and limitations of each method are discussed, specifically concerning detecting blood clots in the oxygenator, as it is concluded that this is the most critical and challenging ECMO component to assess. We investigate the feasibility of solutions proposed in the surrounding literature and explore two areas that hold promise for future research: the analysis of small-scale pressure fluctuations in the circuit, and real-time imaging of the oxygenator. It is concluded that the current methods of detecting blood clots cannot reliably predict clot volume, and their inability to predict clot location puts patients at risk of thromboembolism. It is posited that a more in-depth analysis of pressure readings using machine learning could better provide this information, and that purpose-built imaging could allow for accurate, real-time clotting analysis in ECMO components.


Assuntos
COVID-19 , Oxigenação por Membrana Extracorpórea , Trombose , Humanos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/métodos , Trombose/diagnóstico , Trombose/etiologia , Coagulação Sanguínea , Testes de Coagulação Sanguínea , Oxigenadores/efeitos adversos , COVID-19/complicações
4.
ASAIO J ; 69(11): e455-e459, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37399278

RESUMO

The use of intermittent hemodialysis (iHD), and continuous renal replacement therapy (CRRT), along with extracorporeal membrane oxygenation (ECMO) in patients with acute kidney injury (AKI) and end-stage renal disease (ESRD) is very common. In this technical report, we describe the methods to perform these dialytic therapies safely and effectively using the ECMO circuit in lieu of a separate dialysis catheter. Specifically, we describe in detail how to connect these kidney replacement therapy modalities to a Quadrox, Nautilus, and Cardiohelp HLS (combined oxygenator and pump) oxygenator. The dialysis (iHD or CRRT) inlet is attached to the post-oxygenators Luer-Lock, whereas the return is attached to the pre-oxygenator Luer-Lock, both with a dual lumen pigtail. We also discuss the technical aspects of performing plasmapheresis in conjunction with ECMO and iHD or CRRT. Finally, we highlight the fact that the reported technique does not require modifying the ECMO cannulas/tubing which helps maximize safety.


Assuntos
Terapia de Substituição Renal Contínua , Nautilus , Animais , Humanos , Oxigenadores de Membrana , Diálise Renal , Terapia de Substituição Renal/métodos , Plasmaferese , Oxigenadores
5.
ASAIO J ; 69(10): 924-931, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37314830

RESUMO

Refurbishing single use extracorporeal membrane oxygenation (ECMO) oxygenators for in vitro research applications is common. However, the refurbishment protocols that are established in respective laboratories have never been evaluated. In the present study, we aim at proving the relevance of a well-designed refurbishing protocol by quantifying the burden of repeatedly reused oxygenators. We used the same three oxygenators in 5 days of 6 hours whole blood experiments. During each experiment day, the performance of the oxygenators was measured through the evaluation of gas transfer. Between experiment days, each oxygenator was refurbished applying three alternative refurbishment protocols based on purified water, pepsin and citric acid, and hydrogen peroxide solutions, respectively. After the last experiment day, we disassembled the oxygenators for visual inspection of the fiber mats. The refurbishment protocol based on purified water showed strong degeneration with a 40-50 %-performance drop and clearly visible debris on the fiber mats. Hydrogen peroxide performed better; nevertheless, it suffered a 20% decrease in gas transfer as well as clearly visible debris. Pepsin/citric acid performed best in the field, but also suffered from 10% performance loss and very few, but visible debris. The study showed the relevance of a well-suited and well-designed refurbishment protocol. The distinct debris on the fiber mats also suggests that reusing oxygenators is ill-advised for many experiment series, especially regarding hemocompatibility and in vivo testing. Most of all, this study revealed the relevance of stating the status of test oxygenators and, if refurbished, comment on the implemented refurbishment protocol in detail.


Assuntos
Oxigenação por Membrana Extracorpórea , Oxigenadores de Membrana , Peróxido de Hidrogênio , Pepsina A , Oxigenadores , Técnicas In Vitro , Ácido Cítrico , Água
6.
ASAIO J ; 69(9): 849-855, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37159512

RESUMO

In this retrospective observational cohort study, we aimed to describe the rate of extracorporeal membrane oxygenation (ECMO) circuit change, the associated risk factors and its relationship with patient characteristics and outcome in patients receiving venovenous (VV) ECMO at our center between January 2015 and November 2017. Twenty-seven percent of the patients receiving VV ECMO (n = 224) had at least one circuit change, which was associated with lower ICU survival (68% vs 82% p=0.032) and longer ICU stay (30 vs . 17 days p < 0.001). Circuit duration was similar when stratified by gender, clinical severity, or prior circuit change. Hematological abnormalities and increased transmembrane lung pressure (TMLP) were the most frequent indication for circuit change. The change in transmembrane lung resistance (Δ TMLR) gave better prediction of circuit change than TMLP, TMLR, or ΔTMLP. Low postoxygenator PO 2 was indicated as a reason for one-third of the circuit changes. However, the ECMO oxygen transfer was significantly higher in cases of circuit change with documented "low postoxygenator PO 2 " than those without (244 ± 62 vs. 200 ± 57 ml/min; p = 0.009). The results suggest that circuit change in VV ECMO is associated with worse outcomes, that the Δ TMLR is a better predictor of circuit change than TMLP, and that the postoxygenator PO 2 is an unreliable proxy for the oxygenator function.


Assuntos
Oxigenação por Membrana Extracorpórea , Humanos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Estudos Retrospectivos , Prevalência , Oxigênio , Oxigenadores
7.
Langmuir ; 39(15): 5333-5341, 2023 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-37018043

RESUMO

Nanoparticles with visual imaging capabilities and synergistic therapeutics have a bright future in antitumor applications. However, most of the current nanomaterials lack multiple imaging-guided therapeutic capabilities. In this study, a novel enhanced photothermal photodynamic antitumor nanoplatform with photothermal imaging, fluorescence (FL) imaging, and MRI-guided therapeutic capabilities was constructed by grafting gold, dihydroporphyrin Ce6, and Gd onto α-iron trioxide. This antitumor nanoplatform can convert NIR light into local hyperthermia at a temperature of up to 53 °C under NIR light irradiation, while Ce6 can generate singlet oxygen, which further synergizes the tumor-killing effect. At the same time, α-Fe2O3@Au-PEG-Ce6-Gd can also have significant photothermal imaging effect under light irradiation, which can guide to see the temperature change near the tumor tissue. It is worth noting that α-Fe2O3@Au-PEG-Ce6-Gd can have obvious MRI and FL imaging effects after tail vein injection in mice with blood circulation, realizing imaging-guided synergistic antitumor therapy. α-Fe2O3@Au-PEG-Ce6-Gd NPs provide a new solution for tumor imaging and treatment.


Assuntos
Nanopartículas , Fotoquimioterapia , Animais , Camundongos , Linhagem Celular Tumoral , Peróxido de Hidrogênio , Imagem Multimodal , Oxigenadores , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Fototerapia/métodos
8.
Int J Artif Organs ; 46(5): 295-302, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37051677

RESUMO

OBJECTIVES: Aim of this work was to characterize possible central anatomical configurations in which a future artificial lung (AL) could be connected, in terms of oxygenation performance. METHODS: Pulmonary and systemic circulations were simulated using a numerical and an in vitro approach. The in vitro simulation was carried out in a mock loop in three phases: (1) normal lung, (2) pulmonary shunt (50% and 100%), and (3) oxygenator support in three anatomical configurations: right atrium-pulmonary artery (RA-PA), pulmonary artery-left atrium (PA-LA), and aorta-left atrium (Ao-LA). The numerical simulation was performed for the oxygenator support phase. The oxygen saturation (SO2) of the arterial blood was plotted over time for two percentages of pulmonary shunt and three blood flow rates through the oxygenator. RESULTS: During the pulmonary shunt phase, SO2 reached a steady state value (of 68% for a 50% shunt and of nearly 0% for a 100% shunt) 20 min after the shunt was set. During the oxygenator support phase, physiological values of SO2 were reached for RA-PA and PA-LA, in case of a 50% pulmonary shunt. For the same conditions, Ao-LA could reach a maximum SO2 of nearly 60%. Numerical results were congruous to the in vitro simulation ones. CONCLUSIONS: Both in vitro and numerical simulations were able to properly characterize oxygenation properties of a future AL depending on its placement. Different anatomical configurations perform differently in terms of oxygenation. Right to right and right to left connections perform better than left to left ones.


Assuntos
Pulmão , Artéria Pulmonar , Átrios do Coração , Oxigenadores , Ventiladores Mecânicos , Oxigênio
10.
ASAIO J ; 69(7): e360-e362, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-36867845

RESUMO

A 63-year-old man developed chest pain and dyspnea. Venoarterial-venous extracorporeal membrane oxygenation (ECMO) was applied to the patient due to failing heart after percutaneous coronary intervention. We used an additional ECMO pump without an oxygenator for transseptal left atrial (LA) decompression and performed a heart transplant. Transseptal LA decompression with venoarterial ECMO is not always effective for severe left ventricular dysfunction. Here, we report a case of the effective use of additional ECMO pump without an oxygenator for transseptal LA decompression through controlling the blood flow rate of the transseptal LA catheter.


Assuntos
Fibrilação Atrial , Oxigenação por Membrana Extracorpórea , Masculino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Oxigenadores , Descompressão
11.
ASAIO J ; 69(4): e134-e141, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36780695

RESUMO

Antithrombogenic coatings of artificial surfaces within extracorporeal membrane oxygenation (ECMO) circuits improved its bio- and hemocompatibility. However, there is still a risk of thrombus formation in particular within the membrane oxygenator (MO). Since inflammatory cells are essential components within clots, the aim was to identify the extent of cellular accumulations on gas exchange capillaries from different ECMO systems. Thirty-four MOs (PLS, n = 27, Getinge; Hilite 7000 LT, n = 7, Fresenius Medical Care, Germany) were collected from adult patients. The extent of cellular deposits on gas exchange capillaries was classified using nuclear 4',6-diamidino-2-phenylindole staining and fluorescence microscopy. All Hilite oxygenators exhibited small cellular deposits. In contrast, the cellular distribution was heterogeneous on capillaries from PLS oxygenators: small deposits (34%), clusters (44%) and membrane-spanning cell structures (pseudomembranes) (22%). Overall, the median fluorescence intensity was significantly higher in the PLS group. Nevertheless, within 3 days before MO removal, there was no alteration in critical parameters ( d -dimer and fibrinogen levels, platelet counts, and pressure drop across the MO). In conclusion, despite the histological differences on the gas capillaries from different types of oxygenators, there was no further evidence of increased inflammation and coagulation parameters that indicate clot formation within oxygenators.


Assuntos
Oxigenação por Membrana Extracorpórea , Trombose , Adulto , Humanos , Oxigenadores de Membrana , Capilares/patologia , Coagulação Sanguínea , Testes de Coagulação Sanguínea , Trombose/etiologia , Trombose/patologia , Oxigenadores
12.
Artif Organs ; 47(1): 77-87, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35957489

RESUMO

BACKGROUND: Antithrombogenicity of extracorporeal membrane oxygenation (ECMO) devices, particularly oxygenators, is a current problem, with numerous studies and developments underway. However, there has been limited progress in developing methods to accurately compare the antithrombogenicity of oxygenators. Animal experiments are commonly conducted to evaluate the antithrombogenicity of devices; however, it is challenging to maintain a steady experimental environment. We propose an innovative experimental animal model to evaluate different devices in a constant experimental environment in real-time. METHODS: This model uses two venous-arterial ECMO circuits attached to one animal (one by jugular vein and carotid artery, one by femoral vein and artery) and real-time assessment of thrombus formation in the oxygenator by indocyanine green (ICG) fluorescence imaging. Comparison studies were conducted using three pigs: one to compare different oxygenators (MERA vs. CAPIOX) (Case 1), and two to compare antithrombotic properties of the oxygenator (QUADROX) when used under different hydrodynamic conditions (continuous flow vs. pulsatile flow) (Cases 2 and 3). RESULTS: Thrombi, visualized using ICG imaging, appeared as black dots on a white background in each oxygenator. In Case 1, differences in the site of thrombus formation and rate of thrombus growth were observed in real-time in two oxygenators. In Case 2 and 3, the thrombus region was smaller in pulsatile than in continuous conditions. CONCLUSIONS: We devised an innovative experimental animal model for comparison of antithrombogenicity in ECMO circuits. This model enabled simultaneous evaluation of two different ECMO circuits under the same biological conditions and reduced the number of sacrificed experimental animals.


Assuntos
Oxigenação por Membrana Extracorpórea , Trombose , Animais , Suínos , Verde de Indocianina , Desenho de Equipamento , Oxigenadores , Oxigenação por Membrana Extracorpórea/métodos , Modelos Animais , Trombose/etiologia , Imagem Óptica , Oxigenadores de Membrana/efeitos adversos
13.
Perfusion ; 38(2): 425-427, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-35245992

RESUMO

Few patients with coronavirus disease 2019-associated severe acute respiratory distress syndrome (ARDS) require veno-venous extracorporeal membrane oxygenation (VV-ECMO). Prolonged VV-ECMO support necessitates repeated oxygenator replacement, increasing the risk for complications. Transient hypoxemia, induced by VV-ECMO stop needed for this procedure, may induce transient myocardial ischemia and acutely declining cardiac output in critically ill patients without residual pulmonary function. This is amplified by additional activation of the sympathetic nervous system (tachycardia, pulmonary vasoconstriction, and increased systemic vascular resistance). Immediate reinjection of the priming solution of the new circuit and induced acute iatrogenic anemia are other potentially reinforcing factors. The case of a critically ill patient presented here provides an instructive illustration of the hemodynamic relationships occurring during VV-ECMO support membrane oxygenator exchange.


Assuntos
COVID-19 , Oxigenação por Membrana Extracorpórea , Síndrome do Desconforto Respiratório , Humanos , COVID-19/terapia , Estado Terminal , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/métodos , Hemodinâmica , Oxigenadores , Síndrome do Desconforto Respiratório/etiologia , Síndrome do Desconforto Respiratório/terapia , SARS-CoV-2
14.
Perfusion ; 38(3): 515-522, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-34939512

RESUMO

PURPOSE: The primary aim of this study was to examine the effects of two oxygenator systems on major adverse events and mortality. METHODS: A total of 181 consecutive patients undergoing coronary artery bypass grafting in our clinic were retrospectively analyzed. The patients were divided into two groups according to the oxygenator used: Group M, in which a Medtronic Affinity (Medtronic Operational Headquarters, Minneapolis, MN, USA) oxygenator was used, and Group S, in which a Sorin Inspire (Sorin Group Italia, Mirandola, Italy) oxygenator was used. RESULTS: Group S consisted of 89 patients, whereas Group M included 92 patients. No statistically significant differences were found between the two groups in terms of age (p = .112), weight (p = .465), body surface area (p = .956), or gender (p = .484). There was no statistically significant difference in hemorrhage on the first or second postoperative day (p = .318 and p = .455, respectively). No statistically significant differences were observed in terms of red blood cell (p = .468), fresh frozen plasma (p = .116), or platelet concentrate transfusion (p = .212). Infections, wound complications, and delayed sternal closure were significantly more common in Group M (p = .006, p = .023, and p = .019, respectively). Extracorporeal membrane oxygenators and intra-aortic balloon pumps were required significantly more frequently in Group S (p = .025 and p = .013, respectively). Major adverse events occurred in 16 (18%) patients in Group S and 14 (15.2%) patients in Group M (p = .382). Mortality was observed in six (6.7%) patients in Group S and three (3.3%) patients in Group M (p = .232). No statistically significant difference was found between the two groups in terms of length of hospital stay (p = .451). CONCLUSION: The clinical outcomes of the two oxygenator systems, including mortality, major adverse events, hemorrhage, erythrocyte and platelet transfusions, and length of hospital stay, were similar.


Assuntos
Ponte Cardiopulmonar , Oxigenadores , Humanos , Adulto , Estudos Retrospectivos , Oxigenadores de Membrana , Hemorragia/etiologia , Ponte de Artéria Coronária
15.
Perfusion ; 38(3): 530-538, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35105222

RESUMO

When employing minimal invasive extracorporeal circulation (MiECC), the removal of bubbles in the circuit is important to prevent air embolism. We investigated the bubble removal performance of the FHP oxygenator with a pre-filter and compared it with that of four oxygenators, including the Fusion oxygenator, Quadrox oxygenator, Inspire oxygenator, and FX oxygenator. A closed test circuit filled with an aqueous glycerin solution was used. Air injection (10 mL) was performed prior to the oxygenator, and the number and volume of the bubbles were measured at the inlet and outlet of each oxygenator. At the inlet of the five oxygenators, there were no significant differences in the total number of bubbles detected. At the outlet, bubbles were classified into two groups according to the bubble size: ≥100 µm and <100 µm. Tests were performed at pump flow rates of 4 and 5 L/min. For bubbles ≥100 µm, which are considered clinically detrimental, the FHP was the lowest number and volume of bubbles at both pump flow rates compared to the other oxygenators. Regarding the bubbles <100 µm, the number of bubbles was higher in the FHP than those in others; however, the volume of bubbles was significantly lower at 4 L/min and tended to be lower at 5 L/min. The use of the FHP with the pre-filter removed more bubbles ≥100 µm in the circuit than that by the other oxygenators.


Assuntos
Embolia Aérea , Oxigenadores de Membrana , Humanos , Desenho de Equipamento , Ponte Cardiopulmonar , Oxigenadores , Embolia Aérea/prevenção & controle
16.
Perfusion ; 38(1): 156-164, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-34510993

RESUMO

INTRODUCTION: A high-pressure excursion (HPE) is a sudden increase in oxygenator inlet pressure during cardiopulmonary bypass (CPB). The aims of this study were to identify factors associated with HPE, to describe a treatment protocol utilizing epoprostenol in severe cases, and to assess early outcome in HPE patients. METHODS: Patients who underwent cardiac surgery with cardiopulmonary bypass at Sahlgrenska University Hospital 2016-2018 were included in a retrospective observational study. Pre- and post-operative data collected from electronic health records, local databases, and registries were compared between HPE and non-HPE patients. Factors associated with HPE were identified with logistic regression models. RESULTS: In total, 2024 patients were analyzed, and 37 (1.8%) developed HPE. Large body surface area (adjusted Odds Ratio (aOR): 1.43 per 0.1 m2; 95% confidence interval (CI): 1.16-1.76, p < 0.001), higher hematocrit during CPB (aOR: 1.20 per 1%; (1.09-1.33), p < 0.001), acute surgery (aOR: 2.98; (1.26-6.62), p = 0.018), and previous stroke (aOR: 2.93; (1.03-7.20), p = 0.027) were independently associated with HPE. HPE was treated with hemodilution (n = 29, 78.4%), and/or extra heparin (n = 23, 62.2%), and/or epoprostenol (n = 12, 32.4%). No oxygenator change-out was necessary. While there was no significant difference in 30-day mortality (2.7% vs 3.2%, p = 1.0), HPE was associated with a higher perioperative stroke rate (8.1% vs 1.8%, aOR 5.09 (1.17-15.57), p = 0.011). CONCLUSIONS: Large body surface area, high hematocrit during CPB, previous stroke and acute surgery were independently associated with HPE. A treatment protocol including epoprostenol appears to be a safe option. Perioperative stroke rate was increased in HPE patients.


Assuntos
Ponte Cardiopulmonar , Acidente Vascular Cerebral , Humanos , Ponte Cardiopulmonar/métodos , Epoprostenol , Oxigenadores , Fatores de Risco , Acidente Vascular Cerebral/etiologia
17.
ASAIO J ; 69(3): 324-331, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-35609139

RESUMO

Particulate and gaseous microemboli (GME) are side effects of cardiac surgery that interfere with postoperative recovery by causing endothelial dysfunction and vascular blockages. GME sources during surgery are multiple, and cardiopulmonary bypass (CPB) is contributory to this embolic load. Hematic antegrade repriming (HAR) is a novel procedure that combines the benefits of repriming techniques with additional measures, by following a standardized procedure to provide a reproducible hemodilution of 300 ml. To clarify the safety of HAR in terms of embolic load delivery, a prospective and controlled study was conducted, by applying Doppler probes to the extracorporeal circuit, to determine the number and volume of GME released during CPB. A sample of 115 patients (n = 115) was considered for assessment. Both groups were managed under strict normothermia, and similar clinical conditions and protocols, receiving the same open and minimized circuit. Significant differences in GME volume delivery (control group [CG] = 0.28 ml vs. HAR = 0.08 ml; p = 0.004) and high embolic volume exposure (>1 ml) were found between the groups (CG = 30.36% vs. HAR = 4.26%; p = 0.001). The application of HAR did not represent an additional embolic risk and provided a four-fold reduction in the embolic volume delivered to the patient (coefficient, 0.24; 95% CI, 0.08-0.72; p = 0.01), which appears to enhance GME clearance of the oxygenator before CPB initiation.


Assuntos
Ponte Cardiopulmonar , Embolia Aérea , Humanos , Ponte Cardiopulmonar/efeitos adversos , Ponte Cardiopulmonar/métodos , Embolia Aérea/etiologia , Embolia Aérea/prevenção & controle , Estudos Prospectivos , Desenho de Equipamento , Oxigenadores/efeitos adversos
18.
Perfusion ; 38(5): 983-992, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-35514051

RESUMO

INTRODUCTION: Cardiopulmonary bypass (CPB) machines have oxygenators with integrated filters and unique biocompatible coatings to combat systemic inflammatory response syndrome (SIRS) and mitigate coagulopathy. Contemporary oxygenators have undergone comparative studies; however, our study aimed to identify the most appropriate oxygenator for our regional Cardiothoracic unit in Australasia. METHODS: A prospective audit consecutively recruited one-hundred and fifty patients undergoing cardiac surgery at Waikato Hospital, New Zealand between the periods of 29th January 2018 and 31st July 2018. Fifty patients were recruited for each oxygenator arm: Sorin INSPIRE' (Group-S); Terumo CAPIOX'FX (Group-T); and Medtronic Affinity Fusion' (Group-M). The clinical outcomes were transfusions, chest drain output, reoperation and length of hospital stay (LOHS). Routine blood testing protocol included: haemoglobin, protein, albumin, white cell count (WCC), C-reactive protein (CRP), platelet count and coagulations tests including international normalized ratio (INR). RESULTS: Comparing Groups S, T and M there was no statistical difference in chest drain output (650 vs. 500 vs. 595 ml respectively, p = 0.45), transfusions (61 vs. 117 vs. 70 units, p = 0.67), reoperation (6 vs. 8 vs. 12%, p = 0.99) and LOHS (median 7.4 vs. 7.6 vs. 9.5 days, p = 0.42). Group-T had fewer SIRS cases but similar increase in CRP (p = 0.12) and WCC (p = 0.35). Group-M had a significant rise in post-op INR (p = 0.005) but no associated increase in chest drain output (p = 0.62). Group-S and -M required more 4%-albumin and Group-T had more transfusions. Only fresh frozen plasma (FFP) and red blood cell (RBC) transfusion had a significant relationship with LOHS (p < 0.05). CONCLUSION: Biochemically, there was slight difference among the oxygenators which did not translate into clinical difference in outcomes. The oxygenator design and perfusionist choice aided in our decision-making process.


Assuntos
Ponte Cardiopulmonar , Oxigenadores , Humanos , Testes de Coagulação Sanguínea , Ponte Cardiopulmonar/métodos , Contagem de Plaquetas , Proteína C-Reativa , Albuminas
19.
Perfusion ; 38(5): 887-893, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-35619541

RESUMO

The ProtekDuo, single site dual lumen cannula can be used in a multitude of configurations. In the medical literature, the ProtekDuo is described as right ventricular assist device (RVAD), as left ventricular assist device (LVAD), as biventricular assist device (BiVAD) when combined with an Impella device or other LVAD's, as double lumen drainage cannula on cardiopulmonary bypass (CPB), as RVAD with oxygenator, in veno-pulmonary (V-P) ECMO configuration, venovenous-pulmonary (VV-P) ECMO configuration with additional drainage cannula, and in veno-venopulmonary (V-VP) ECMO configuration as double lumen return cannula. Improvements in flow and oxygenation have been recognized in various settings and need further scientific evaluation. We summarized the above-mentioned configurations, technical aspects, and the present literature available for the ProtekDuo.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Coração Auxiliar , Humanos , Cânula , Ponte Cardiopulmonar , Oxigenadores
20.
ASAIO J ; 69(3): 247-253, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-35749749

RESUMO

This systematic review summarizes the major developments in extracorporeal membrane oxygenation (ECMO) circuitry in pediatrics over the past 20 years and demonstrates the impacts of those developments on clinical outcomes. This systematic review followed structured Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A total of 1987 studies were retrieved, of which 82 were included in the final analysis. Over the past 20 years, ECMO pumps have shifted from roller pumps to centrifugal pumps. Silicone and polypropylene hollow fiber membrane oxygenators were initially used but have been replaced by polymethylpentene hollow fiber membrane oxygenators, with other ECMO components poorly reported. Considerable variability in mortality was found across studies and there was no statistical difference in mortality rates across different periods. The duration of ECMO and other outcome measures were inconsistently reported across studies. This systematic review demonstrated technological developments in pumps and oxygenators over the last two decades, although patient mortality rates remained unchanged. This could be because of ECMO support applied to patients in more critical conditions over the years. We also highlighted the limitations of methodology information disclosure and outcome measures in current ECMO studies, showing the need of reporting standardization for future ECMO studies.


Assuntos
Oxigenação por Membrana Extracorpórea , Humanos , Criança , Oxigenação por Membrana Extracorpórea/métodos , Oxigenadores
SELEÇÃO DE REFERÊNCIAS